Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-06-06-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212743
DEA: 030H26U4
EFIS: 0317000247
DIST-CO-RTE-PM03-PLA-65-R5.0/R6.6
Award Date02/14/2018
Closeout Date10/21/2022
Work DescriptionNORTHBOUND WIDENING AND RAMP IMPROVEMENTS.
Location DescriptionPLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 12/18/2017)

Sample Information

Sample Taken Date06/06/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/11/2018
Sample typeDepartment Acceptance A brief description of the sampleFlash welded 7 x 10 rebar hoops
The quantity of what the sample constitutes Lot 9 150 of 600 total From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byHolck
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler9166620354
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Tracy CA Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS44-005-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4074933
Hoop Manufacturer Lot Number(s)9 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop10'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCmc tracy
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-06-06-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/12/2018Fred
Yes
06/20/2018Bar Broke in Heat Affected Area; OK Necking
2018-06-06-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/12/2018Fred
Yes
06/20/2018Bar Broke; OK Necking
2018-06-06-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/12/2018Fred
Yes
06/20/2018Bar Broke; OK Necking
2018-06-06-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory06/12/2018Fred
Yes
06/20/2018Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-06-06-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-06-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-06-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-06-06-3-4 CTM 670-December 2013 (Verified)