Summary for Test 2018-05-25-3-1

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 212354
DEA: 044K8504
EFIS: 0417000378
DIST-CO-RTE-PM04-MRN,MTRN-1-22.8, 22.80
Award Date06/21/2017
Closeout Date12/16/2021
Work DescriptionGiacomini Creek Bridge, Construct sheet pile wall, replace culvert
Location DescriptionROUTE 1, AT POSTMILE 22.8, NEAR BOLINAS, AT 0.52 MILES NORTH OF HORSESHOE HILL RD., MARIN COUNTY SLIPOUT, CONSTRUCT SOLDIER PILE WALL
QA Service Level1 (Verified on 05/01/2017)

Sample Information

Sample Taken Date05/25/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/25/2018
Sample typeQuality Assurance A brief description of the sample3/4 X 4-1/2, 3/4 X 5-1/2, 7/8 X 19-1/2
The quantity of what the sample constitutesLot of 28 From where was the sample collectedFabricator
First name of sampler or witnessed byScott Last name of sampler or witnessed byLeavitt
Title of samplerQA Inspector Telephone number of sampler510 590-0116
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namePortland Bolt Manufacturing Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS28-126-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)110135-1, 110135-2
Heat Number(s)NF16100667, 10483100, 3065481 Nut Mfg. Lot Number(s)400279E
Washer Mfg. Lot Number(s)0118-742 Bolt SpecificationA325, A325, A449
Bolt Length(s)4-1/2, 5-1/2, 19-1/2 Nut SpecificationA563DH
Washer SpecificationF436-1 FinishHDG, HDG, HDG
Diameter/Size3/4, 3/4, 7/8 Bolt Mfg. Lot NumberNucor, Fontana Fasteners, Portland Bolt
Rocap Test Requirement(s)Yes, Yes, No Lubricant Requirements(s)Yes, Yes

Test Details

DIME Sample ID: 2018-05-25-3
DIME Test ID: 2018-05-25-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-06-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/30/2018
UTM: 400KIP
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
13AA449 Bolt0.4626071227013141111861754801A449 Bolt

General comments (publicly viewable) (Max 1000 characters): A449 Bolt
Test Graph
Source: Partner Data Point File

Test was verified on 5/31/2018