Summary for Test 2018-01-18-3-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date01/18/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/18/2018
Sample typeQuality Control A brief description of the sample2 pints 204,chp,zcure,8020
The quantity of what the sample constitutes25000 gal From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namekwik Bond, Benecia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)1820589688
Batch number1820589688 Mix number1820589688

Test Details

DIME Sample ID: 2018-01-18-3
DIME Test ID: 2018-01-18-3-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2018-02-01

Test Results


Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 02/01/2018
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 21.4
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.14
Volatile content (ASTM D 2369) 30% max: 25.7
Flash point (ASTM D 3828) more than 180 deg F: 180
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 604
Tack free time, 400 minutes max: 330
General comments (publicly viewable) (Max 1000 characters): HMWM batch#: 18-20-589688 is satisfactory for use ( bond test result accepted suppliers test result).

Test was verified on 4/19/2018