Summary for Test 2018-01-29-2-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 209146 DEA: 06471504 EFIS: 0600000464 COOP: 061549 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-39.6/41.3 |
Award Date | 02/24/2017 |
Closeout Date | 03/03/2020 |
Work Description | RECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT. |
Location Description | TULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD |
QA Service Level | 1 (Verified on 10/08/2013) |
Sample Information
Sample Taken Date | 01/29/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/31/2018 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 388 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Leach |
Title of sampler | QA | Telephone number of sampler | 916-243-5195 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CK Johnson Industries | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S38-019-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 75C275BA30G 75C325BA30G 100C375BA30G |
---|---|---|---|
Heat Number(s) | DL17103753, DL17103750, DL17101702 | Nut Mfg. Lot Number(s) | DL17105148, DL17105148, DL17103954 |
Washer Mfg. Lot Number(s) | D4421, D4421, 174328 | Bolt Specification | A325 |
Bolt Length(s) | 2-3/4, 3-1/4, 3-3/4 | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 3/4 1'' | Bolt Mfg. Lot Number | 397031A, 397036A, 397956A |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2018-01-29-2
DIME Test ID: 2018-01-29-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-02-13
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/02/2018
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1B | S29011918 | 3/4\" | 47230 | 210.1 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 2/6/2018 ✔