Test 2016-07-26-7-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 211047
DEA: 081C0914
EFIS: 0814000223
DIST-CO-RTE-PM08-RIV-60-R12.2/22.1&26.5/30.4
Work DescriptionMILL AND OVERLAY MAINLINE PAVEMENT, SHOULDERS, RAMPS, INCLUDE DIGOUTS
Location DescriptionMILL AND OVERLAY MAINLINE PAVEMENT, SHOULDERS, RAMPS, INCLUDE DIGOUTS
Sample Information
Sample Taken Date7/26/2016 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/26/2016
Sample typeAnnual Source Testing A brief description of the sampleOne inch PCC Aggregates
The quantity of what the sample constitutes10 Bags From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Laboratory sample identification6295B
The fabricator/manufacturer/facility nameRobertsons Ready Mix - Cabazon Quarry Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)SMARA 91 33 0008
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedRobertsons Stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2016-07-26-7
DIME Test ID: 2016-07-26-7-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-07-08
Test Results

What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Sebastian Ferrer
Date of test: 07/27/2016
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:84 %
Cumulative percent passing the 3/4 in. sieve:52 %
Cumulative percent passing the 1/2 in. sieve:14 %
Cumulative percent passing the 3/8 in. sieve:3 %
Cumulative percent passing the #4 sieve:1 %
Cumulative percent passing the #8 sieve:1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/08/2019