Summary for Test 2016-04-18-4-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 210873
DEA: 044H9004
EFIS: 0413000300
DIST-CO-RTE-PM04-SF-280-R0.1,R1.5
Award Date12/14/2015
Closeout Date12/27/2017
Work DescriptionCONCRETE BARRIER, RETAINING WALL, SHOULDER AND SIDEWALK WIDENING
Location DescriptionIN THE CITY AND COUNTY OF SANFRANCISCO AT ROUTE 280 SOUTHBOUND OFF-RAMP TO JOHN DALY BOULEVARD ANDAT SAN JOSE AVENUE OVERCROSSING
QA Service Level1 (Verified on 01/25/2016)

Sample Information

Sample Taken Date04/18/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/21/2016
Sample typeInformational A brief description of the sampleconcrete cylinder
The quantity of what the sample constitutes1 concrete cylinder From where was the sample collectedJob Site
First name of sampler or witnessed byNick Last name of sampler or witnessed byTsai
Title of samplerSR Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namefield Transportation Laboratory (TL) Number180401
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberna
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedna
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedfield Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-04-18-4
DIME Test ID: 2016-04-18-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-05-16

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 05/16/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Maximum load on cylinder 1: 140724 lb
Type of fracture pattern of cylinder 1: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Compressive strength of cylinder (to nearest 10 psi): 4980 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 1

Test was verified on 5/16/2016