Test 2021-06-18-29-1 (CONCLP 4-16) Summary

Project Information
Project IdentifiersProject ID: 215523
DEA: 120S2004
EFIS: 1219000105
DIST-CO-RTE-PM12-ORA-22,57-R2.7/R11.9,18.8
Work DescriptionPLACE POLYESTER CONCRETE, REPLACE JOINT SEALS AND TREAT BRIDGE DECK.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS ON ROUTE 22 FROM GARDEN GROVE BOULEVARD UNDERCROSSING TO GLASSELL STREET UNDERCROSSING AND ON ROUTE 57 AT BASTANCHURY ROAD UNDERCROSSING
Sample Information
Sample Taken Date6/18/2021 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/21/2021
Sample typeQuality Control A brief description of the sample2 pints 204, chp, z cure, 8020
The quantity of what the sample constitutes25000 gallons From where was the sample collectedSource
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byTikusis
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberC943077
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeMethacrylate Mfg. Lot Number(s)2170790889
Batch number2170790889 Mix number3524
Test Details
DIME Sample ID: 2021-06-18-29
DIME Test ID: 2021-06-18-29-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-07-30
Test Results

Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 07/15/2021
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20.86
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 7.58
Volatile content (ASTM D 2369) 30% max: 22.29
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 816.343
Tack free time, 400 minutes max: 280
General comments (publicly viewable) (Max 1000 characters): Bond Strength and Tack Free Accepted Based On Supplier Results.

Test was verified on 07/30/2021