Summary for Test 2021-01-22-1-6

Test performed: CTM 527-February 2014

Project Information

Project IdentifiersProject ID: 213596
DEA: 051C8904
EFIS: 0513000009
DIST-CO-RTE-PM05-MON-101-87.3/R91.5
Award Date12/13/2018
Closeout Date08/23/2023
Work DescriptionPRECAST CONC PVMT, CRACK AND SEAT PAVEMENT AND RECONSTRUCT RAMPS.
Location DescriptionMONTEREY COUNTY IN SALINAS FROM EAST MARKET STREET UNDERCROSSING TO 0.3 MILE SOUTH OF ESPINOSA ROAD
QA Service Level1 (Verified on 01/04/2019)

Sample Information

Sample Taken Date01/22/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/22/2021
Sample typeQuality Assurance A brief description of the sampleRapid Setting Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSupplier
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM214101 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS Rapid Set Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCTS
MillJuarez Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2021-01-22-1
DIME Test ID: 2021-01-22-1-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 527-February 2014: Method of Test for Expansion in Water and Contraction in Air of Portland Cement Mortar
Test Release Date: 2021-02-09

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 02/02/2021
Initial Length of Specimen 1: .2812 in
Expansion Length of Specimen 1: .2820 in
Percent Expansion of Specimen 1: 0.008000 %
Contraction Length of Specimen 1: .2801 in
Percent Contraction of Specimen 1: 0.019000 %
Initial Length of Specimen 2: .2595 in
Expansion Length of Specimen 2: .2603 in
Percent Expansion of Specimen 2: 0.008000 %
Contraction Length of Specimen 2: .2584 in
Percent Contraction of Specimen 2: 0.019000 %
Initial Length of Specimen 3: .2647 in
Expansion Length of Specimen 3: .2655 in
Percent Expansion of Specimen 3: 0.008000 %
Contraction Length of Specimen 3: .2636 in
Percent Contraction of Specimen 3: 0.019000 %
Initial Length of Specimen 4: .2768 in
Expansion Length of Specimen 4: .2776 in
Percent Expansion of Specimen 4: 0.008000 %
Contraction Length of Specimen 4: .2758 in
Percent Contraction of Specimen 4: 0.018000 %
Average change in length in water: 0.0080 %
Average change in length in air: 0.0187 %
General comments (publicly viewable) (Max 1000 characters): @ 4:05

Test was verified on 2/9/2021