Sample Record

Owner Lab

  • CT HQ - Sacramento Cement Testing Laboratory

DIME Sample ID 2021-01-22-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213596
DEA: 051C8904
EFIS: 0513000009
DIST-CO-RTE-PM05-MON-101-87.3/R91.5
Award Date12/13/2018
Closeout Date08/23/2023
Work DescriptionPRECAST CONC PVMT, CRACK AND SEAT PAVEMENT AND RECONSTRUCT RAMPS.
Location DescriptionMONTEREY COUNTY IN SALINAS FROM EAST MARKET STREET UNDERCROSSING TO 0.3 MILE SOUTH OF ESPINOSA ROAD
QA Service Level1 (Verified on 01/04/2019)

Sample Information

Sample Taken Date01/22/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/22/2021
Sample typeQuality Assurance A brief description of the sampleRapid Setting Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSupplier
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM214101 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS Rapid Set Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCTS
MillJuarez Type of Cementitious MaterialRapid Set Cement

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-01-22-1-2ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)BL, CT HQ - Sacramento Cement Testing Laboratory01/29/2021
Yes
02/09/20213 day cubes
2021-01-22-1-4CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic CementBenjamin Lenz, CT HQ - Sacramento Cement Testing Laboratory01/29/2021Benjamin Lenz
Yes
02/09/20213 day test -- Two specimen breaks were outside allowable range per Section 13 of ASTM C109-16. Average compressive strength shown is based on remaining 4 specimens.
2021-01-22-1-5ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)Benjamin Lenz, CT HQ - Sacramento Cement Testing Laboratory02/09/2021Benjamin Lenz
Yes
02/09/2021@ 11:45
2021-01-22-1-6CTM 527-February 2014: Method of Test for Expansion in Water and Contraction in Air of Portland Cement MortarBenjamin Lenz, CT HQ - Sacramento Cement Testing Laboratory02/02/2021Benjamin Lenz
Yes
02/09/2021@ 4:05

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-01-22-1-2 ASTM C109-16a (Verified)
DIME Test ID: 2021-01-22-1-4 CTM 553-1 (Verified)
DIME Test ID: 2021-01-22-1-5 ASTM C1038-14b (Verified)
DIME Test ID: 2021-01-22-1-6 CTM 527-February 2014 (Verified)