Test 2020-11-16-1-3 (ASTM C109-16a) Summary

Project Information
Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
Sample Information
Sample Taken Date11/16/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/16/2020
Sample typeControl Sample A brief description of the sampleType I/II Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Laboratory sample identificationCM209009
The fabricator/manufacturer/facility nameGCC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeCementitious BrandGCC of America
MillPueblo Colorado Type of Cementitious MaterialType II Cement
Test Details
DIME Sample ID: 2020-11-16-1
DIME Test ID: 2020-11-16-1-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2021-01-21
Test Results

Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: BL
Date of test: 12/17/2020
Age of specimen: 23 days
The amount of flow : 117.00 %
The amount of water used : 48.4 %
Compressive strength of 1st specimen : 5626 psi
Compressive strength of 2nd specimen: 5646 psi
Compressive strength of 3rd specimen : 5543 psi
Average Compressive strength (to nearest 10 psi): 5610 psi
General comments (publicly viewable) (Max 1000 characters): 28 day test @ 12:05
Test Graph
Source: Bluehill Data Point File

Source: Bluehill Data Point File

Source: Bluehill Data Point File

Test was verified on 01/21/2021