Print Report | Back to Test Summary

Testing Report for 2021-06-28-21-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080C2514
EFIS: 0816000076
Project ID: 212112
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Matt Antonelli
Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2021-06-28-21
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 6/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 6/30/2021
The quantity of what the sample constitutes: 3 Bags Combined Agg., 1 Bag Rap
A brief description of the sample: PSUE 3/4" HMA-A-SP R15 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0395A-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Irwindale

Material Information

Source Identification (SMARA or name of Pit): 91-19-0035
The fabricator's/manufacturer's product name for the sample: 3/4 HMA-A-SP R15
The fabricator/manufacturer designation for the sample:
The plant number: 224112A IRW SJR
A detailed description of where the material sample was collected: Belt Cut at Vulcan Irwindale Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-06-28-21-7
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Date Tested: 7/7/2021
Verified Date: 7/9/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Percentage of fractured, coarse, 2 faced particles tested: 96 %
Percentage of fractured, coarse, 1 faced particles tested: 98 %
Percentage of fractured, fine, 1 faced particles tested: 100 %