Print Report | Back to Test Summary

Testing Report for 2021-02-02-7-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-6.7/R25.1
Work Description: Remove concrete pavement and base, and place HMA and JPCP
Location Description: ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Elvira Lenart Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-02-02-7
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 02/02/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/04/2021
The quantity of what the sample constitutes: 12 Bags Of Aggregate, 3 Bags RAP
A brief description of the sample: JMF 3/4" HMA-A-SP R24 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0134A-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: California Commercial Asphalt - Coachella

Material Information

Source Identification (SMARA or name of Pit): 91-33-0084
The fabricator's/manufacturer's product name for the sample: 3/4 HMA-A-SP R24
The fabricator/manufacturer designation for the sample:
The plant number: 43417615
A detailed description of where the material sample was collected: Belt Cut at California Commercial Asphalt Coachella Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-02-02-7-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 02/11/2021
Date Tested: 02/05/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test: Combined Virgin Aggregate Gradation
Additional Comments When Verified :

Submitted Test Results

Cumulative percent passing the 3 in. sieve 100 %
Cumulative percent passing the 2 1/2 in. sieve 100 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 91 %
Cumulative percent passing the #8 sieve 77 %
Cumulative percent passing the #16 sieve 61 %
Cumulative percent passing the #30 sieve 45 %
Cumulative percent passing the #50 sieve 30 %
Cumulative percent passing the #100 sieve 18 %
Cumulative percent passing the #200 sieve 11 %