Summary for Test 2020-11-20-3-6

Test performed: ASTM A615-15

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date11/20/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/30/2020
Sample typeQuality Assurance A brief description of the sample#8 Thread Bar
The quantity of what the sample constitutes456 ea. From where was the sample collectedSource
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerQA Inspector Telephone number of sampler17142674733
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNucor Skyline Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL78-109-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade80
Threaded Bar TypeDeformed Rebar Size#8
Nut Specification for Threaded BarASTM A29 System ManufacturerNucor
Epoxy Coating ColorNA Threaded Bar Application
Coating StandardsUncoated Bar Heat Number(s)3700015150, 3700015151, 3700015152, BR1910025
Nut Heat Number(s)8391409, 8391106 Bar Lot NumberN/A
Nut Lot Number5382, 5421, 5429 Coupler Heat Number(s)N/A
Coupler GradeN/A

Test Details

DIME Sample ID: 2020-11-20-3
DIME Test ID: 2020-11-20-3-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-12-08

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 12/07/2020
UTM: 400kip
Temperature: 72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1No.8/25mm0.79102672921020Bar Nut Stripped 3700008046 5382fsaylor

General comments (publicly viewable) (Max 1000 characters): Bar Nut Stripped 3700008046 5382
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.