Summary for Test 2020-11-18-1-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/18/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/01/2020 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM F1554-15 Gr. 55 anchor bolts |
| The quantity of what the sample constitutes | 240 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
| Title of sampler | QA Inspector | Telephone number of sampler | 213 435 4055 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | A and M Nut and Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-295-20 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 6215177905 | |
| Washer Mfg. Lot Number(s) | 183679 | Bolt Specification | ASTM F1554 Grade 55 |
| Bolt Length(s) | 36" | Nut Specification | ASTM A563 DH |
| Washer Specification | ASTM F436 | Finish | hot dipped galvanized |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 3096588 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2020-11-18-1
DIME Test ID: 2020-11-18-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-12-15
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 12/04/2020
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 32553-6215177905 | 94641 | A563 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 12/15/2020 ✔