Summary for Test 2015-03-24-4-1
Test performed: CTM 521-November 2014
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Project Information
| Project Identifiers | Project ID: 7409 DEA: 07245403 EFIS: 0700000431 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-31.1/32.3 |
| Award Date | 02/29/2012 |
| Closeout Date | 10/27/2016 |
| Work Description | Construct Connector between I-10 and I-605 (Design Build Project) LA-10-31.1/32.3, LA-605-R20.2/20.6 |
| Location Description | 10 & 605 IC |
| QA Service Level | 1 (Verified on 03/14/2013) |
Sample Information
| Sample Taken Date | 03/24/2015 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2015 |
| Sample type | Quality Control | A brief description of the sample | concrete cylinders |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | oscar | Last name of sampler or witnessed by | Rodriguez |
| Title of sampler | asr | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | site | Transportation Laboratory (TL) Number | 60513 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
| Structure name | Unknown | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | S75099 |
|---|---|---|---|
| The truck number from where the sample was collected | 373 | The batch plant ticket number from where the sample was collected | load 12 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | frame 4 soffit and stem pour 1 span 13and14 | Where the material sample would have been placed if not sampled | Not set |
| From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-03-24-4
DIME Test ID: 2015-03-24-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-04-22
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 04/21/2015
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 142320 lb
Maximum load on cylinder 2: 141530 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 5034.3 psi
Compressive strength of cylinder 2: 4988.7 psi
Compressive strength (to nearest 10 psi): 5010 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/22/2015 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.