Summary for Test 2020-11-04-16-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-6.7/R25.1 |
| Award Date | 11/26/2019 |
| Closeout Date | 11/01/2023 |
| Work Description | Remove concrete pavement and base, and place HMA and JPCP |
| Location Description | ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON. |
| QA Service Level | 1 (Verified on 01/09/2020) |
Sample Information
| Sample Taken Date | 11/04/2020 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/05/2020 |
| Sample type | Quality Assurance | A brief description of the sample | 6x12 |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | DAVID | Last name of sampler or witnessed by | PASOS |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 1012-01 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | CEMEX RIALTO | Transportation Laboratory (TL) Number | 01 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1610974 |
|---|---|---|---|
| The truck number from where the sample was collected | 10070485 | The batch plant ticket number from where the sample was collected | 29324439 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Jobsite | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2020-11-04-16
DIME Test ID: 2020-11-04-16-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-11-12
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 11/11/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 120880 lb
Maximum load on cylinder 2: 121390 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4247.4 psi
Compressive strength of cylinder 2: 4294.0 psi
Compressive strength (to nearest 10 psi): 4270 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/12/2020 ✔