Summary for Test 2020-10-28-1-11
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 213749 DEA: 120C1104 EFIS: 1200000633 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-20.3/21.6 |
| Award Date | 04/19/2019 |
| Closeout Date | 05/28/2024 |
| Work Description | SR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
| Sample Taken Date | 10/28/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/28/2020 |
| Sample type | Quality Assurance | A brief description of the sample | Anchor Bolt Samples |
| The quantity of what the sample constitutes | 400 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 1-385-447-0624 |
| Laboratory sample identification | na | Linked DIME Sample ID | na |
| The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | na |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-050-20 | Structure unique identifier | |
| Structure name | na | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 1202022608 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | F1554-55 |
| Bolt Length(s) | 5'-0" | Nut Specification | na |
| Washer Specification | na | Finish | HDG/ Plain |
| Diameter/Size | 2-1/2" | Bolt Mfg. Lot Number | na |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2020-10-28-1
DIME Test ID: 2020-10-28-1-11
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-11-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/04/2020
UTM: 67kip
Temperature: 72 f
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1202022658 | 0.504 | 0.2 | 64027 | 90399 | 26.9 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 11/4/2020 ✔