Summary for Test 2020-09-01-21-2
Test performed: ASTM C109-16aProject Information
Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/01/2020 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/01/2020 |
Sample type | Proficiency | A brief description of the sample | pozzolan |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Other |
First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM208068 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CCRL | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | CCRL |
---|---|---|---|
Mill | CCRL Pozzolan | Type of Cementitious Material | Class F or N Flyash |
Test Details
DIME Sample ID: 2020-09-01-21
DIME Test ID: 2020-09-01-21-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2022-07-11
Test Results
Will control cubes be used per ASTM C311?: yes
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 09/22/2020
Age of specimen: 7 days
The amount of flow : 133 %
The amount of water used : 47 %
Compressive strength of 1st specimen : 4721 psi
Compressive strength of 2nd specimen: 5064 psi
Compressive strength of 3rd specimen : 4832 psi
Average Compressive strength (to nearest 10 psi): 4870 psi
Average Compressive strength (to nearest 10 psi) control group: 4850 psi
Strength Activity Index of Portland Cement per ASTM C109: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/11/2022 ✔