Summary for Test 2020-09-01-20-2

Test performed: ASTM C109-16a

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/01/2020 Sample Unique Key20
Date that the sample was received by the laboratory/organization performing the testing09/01/2020 Sample typeProficiency
A brief description of the samplepozzolan The quantity of what the sample constitutes1 bag
From where was the sample collectedOther First name of sampler or witnessed byna
Last name of sampler or witnessed byna Title of sampler
Telephone number of sampler Laboratory sample identificationCM208067
Linked DIME Sample ID The fabricator/manufacturer/facility nameCCRL
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Pozzolan Type of Cementitious MaterialClass F or N Flyash

Test Details

DIME Sample ID: 2020-09-01-20
DIME Test ID: 2020-09-01-20-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2022-07-11

Test Results


Will control cubes be used per ASTM C311?: yes
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 09/22/2020
Age of specimen: 7 days
The amount of flow : 132 %
The amount of water used : 47.0 %
Compressive strength of 1st specimen : 4830 psi
Compressive strength of 2nd specimen: 4851 psi
Compressive strength of 3rd specimen : 4802 psi
Average Compressive strength (to nearest 10 psi): 4830 psi
Average Compressive strength (to nearest 10 psi) control group: 4850 psi
Strength Activity Index of Portland Cement per ASTM C109: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/11/2022 ✔