Summary for Test 2020-09-18-18-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 214847
DEA: 074W8204
EFIS: 0720000009
DIST-CO-RTE-PM07-VEN-101-17.7
Award Date05/21/2020
Closeout Date08/02/2021
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE AND PLACE CONCRETE BARRIER.
Location DescriptionVENTURA COUNTY IN CAMARILLO AT CENTRAL AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/08/2020)

Sample Information

Sample Taken Date09/18/2020 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing09/19/2020 Sample typeQuality Control
A brief description of the samplePCC 6"x12" test cylinder The quantity of what the sample constitutes1 girder
From where was the sample collectedManufacturer First name of sampler or witnessed byJorge
Last name of sampler or witnessed byGarcia Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCon-Fab California, LLC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC-S90-0F
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2498
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2020-09-18-18
DIME Test ID: 2020-09-18-18-1
Testing Lab: Con-Fab California Corporation - Shafter
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-09-24

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jorge Garcia
Date of test: 09/19/2020
Capped in accordance with?: ASTM C1231
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 149865 lb
Maximum load on cylinder 2: 153485 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 1 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5370 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/24/2020 ✔