Summary for Test 2020-09-18-18-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 214847 DEA: 074W8204 EFIS: 0720000009 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-101-17.7 |
| Award Date | 05/21/2020 |
| Closeout Date | 08/02/2021 |
| Work Description | REPLACE STRUCTURAL CONCRETE BRIDGE AND PLACE CONCRETE BARRIER. |
| Location Description | VENTURA COUNTY IN CAMARILLO AT CENTRAL AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 07/08/2020) |
Sample Information
| Sample Taken Date | 09/18/2020 | Sample Unique Key | 18 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2020 |
| Sample type | Quality Control | A brief description of the sample | PCC 6"x12" test cylinder |
| The quantity of what the sample constitutes | 1 girder | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jorge | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Con-Fab California, LLC | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SCC-S90-0F |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 2498 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | back of truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2020-09-18-18
DIME Test ID: 2020-09-18-18-1
Testing Lab: Con-Fab California, LLC
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-09-24
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jorge Garcia
Date of test: 09/19/2020
Capped in accordance with?: ASTM C1231
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 149865 lb
Maximum load on cylinder 2: 153485 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 1 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5370 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/24/2020 ✔