Sample Record

Owner Lab

  • Con-Fab California, LLC

DIME Sample ID 2020-09-18-18

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214847
DEA: 074W8204
EFIS: 0720000009
DIST-CO-RTE-PM07-VEN-101-17.7
Award Date05/21/2020
Closeout Date08/02/2021
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE AND PLACE CONCRETE BARRIER.
Location DescriptionVENTURA COUNTY IN CAMARILLO AT CENTRAL AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/08/2020)

Sample Information

Sample Taken Date09/18/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/19/2020
Sample typeQuality Control A brief description of the samplePCC 6"x12" test cylinder
The quantity of what the sample constitutes1 girder From where was the sample collectedManufacturer
First name of sampler or witnessed byJorge Last name of sampler or witnessed byGarcia
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California, LLC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSCC-S90-0F
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2498
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-09-18-18-1ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensJorge Garcia, Con-Fab California, LLC09/19/2020Jorge Garcia
Yes
09/24/2020
2020-09-18-18-2CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)Jorge Garcia, Con-Fab California, LLC09/18/2020Jorge Garcia
Yes
10/07/2020

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-09-18-18-1 ASTM C39-10 (Verified)
DIME Test ID: 2020-09-18-18-2 CTM TEMP1-16 (Verified)