Summary for Test 2020-07-17-26-9

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/17/2020 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2020
Sample typeProficiency A brief description of the sampleCCRL 217
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerCCRL 217 Telephone number of sampler
Laboratory sample identificationCM208217 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCCRL Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2020-07-17-26
DIME Test ID: 2020-07-17-26-9
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2021-08-19

Test Results


Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 09/01/2020
Type of Water Used: Potable
Initial time of setting: 186 min
Final time of setting: 285 min
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/19/2021