Summary for Test 2020-01-14-8-2

Test performed: ASTM C109-16a

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/14/2020 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing01/14/2020 Sample typeAnnual Source Testing
A brief description of the sampleType IP The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of sampler
Telephone number of sampler Laboratory sample identificationCM205010
Linked DIME Sample ID The fabricator/manufacturer/facility nameSMRG
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandSalt River Materials Group
MillClarkdale Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2020-01-14-8
DIME Test ID: 2020-01-14-8-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2021-06-23

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: Anthony Valdez Jr
Date of test: 08/27/2020
Age of specimen: 3 days
The amount of flow : 115 %
The amount of water used : 47.3 %
Compressive strength of 1st specimen : 2544 psi
Compressive strength of 2nd specimen: 2902 psi
Compressive strength of 3rd specimen : 2517 psi
Average Compressive strength (to nearest 10 psi): 2650 psi
General comments (publicly viewable) (Max 1000 characters): 3 day test -- Specimen 2 break was outside allowable range per Section 14 of ASTM C109-20b. Correct final result is 2530 PSI.

Test was verified on 6/23/2021 ✔