Summary for Test 2020-07-15-7-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214601
DEA: 041J5694
EFIS: 0419000313
DIST-CO-RTE-PM04-SM-101-0.0/21.8
Award Date12/03/2019
Closeout Date09/28/2022
Work DescriptionSan Mateo US 101 Express Lanes North
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date07/15/2020 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing07/15/2020 Sample typeQuality Assurance
A brief description of the sampleASTM A325 1-1/4"x 4-1/4 " Bolt The quantity of what the sample constitutes33 pcs
From where was the sample collectedSource First name of sampler or witnessed byMichael
Last name of sampler or witnessed byKopenski Title of samplerQA
Telephone number of sampler(310) 745-9655 Laboratory sample identificationL149-073-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameStructural and Steel Products
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)060920ER
Heat Number(s)Bolt 100793373, Nut DL17100198 Nut Mfg. Lot Number(s)388517A
Washer Mfg. Lot Number(s) Bolt SpecificationASTM A325
Bolt Length(s)4-1/4" Nut SpecificationASTM A563
Washer Specificationn/a FinishMech.Zinc Galv. ASTM B695
Diameter/Size1-1/4"x 4-1/4" Bolt Mfg. Lot Number421043A
Rocap Test Requirement(s)060920ER Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2020-07-15-7
DIME Test ID: 2020-07-15-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-08-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 08/18/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
15A388517A149929Proff Load

General comments (publicly viewable) (Max 1000 characters): Proff Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 8/19/2020