Summary for Test 2020-07-15-4-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
Award Date | 12/03/2019 |
Closeout Date | 09/28/2022 |
Work Description | San Mateo US 101 Express Lanes North |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 07/15/2020 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/15/2020 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A325 1- 1/4" x 3- 3/4" HH Bolts |
The quantity of what the sample constitutes | 27 pcs | From where was the sample collected | Source |
First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Kopenski |
Title of sampler | QA | Telephone number of sampler | (310) 745-9655 |
Laboratory sample identification | L149-073-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 060920CR |
---|---|---|---|
Heat Number(s) | Bolt 100893998, Nut DL17100198, Washer 4171854 | Nut Mfg. Lot Number(s) | 388517A |
Washer Mfg. Lot Number(s) | D7043 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 3- 3/4" | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | Mech.Zinc Galv. ASTM B695 |
Diameter/Size | 1-1/4"x3-3/4" | Bolt Mfg. Lot Number | 416756A |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2020-07-15-4
DIME Test ID: 2020-07-15-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-08-19
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/18/2020
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2A | 416756A | 1.2500 | 27 | 0.12 | 6.00 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/19/2020 ✔