Summary for Test 2020-07-15-3-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
| Award Date | 12/03/2019 |
| Closeout Date | 09/28/2022 |
| Work Description | San Mateo US 101 Express Lanes North |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 07/15/2020 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/15/2020 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2"x 2-3/4" HH A325 Bolt | The quantity of what the sample constitutes | 82 total |
| From where was the sample collected | Source | First name of sampler or witnessed by | Michael |
| Last name of sampler or witnessed by | Kopenski | Title of sampler | QA |
| Telephone number of sampler | (310) 745-9655 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Structural and Steel Products | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L149-073-20 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 060920BR |
|---|---|---|---|
| Heat Number(s) | Bolt NF15203266, Nut 100789206, Washer 136431 | Nut Mfg. Lot Number(s) | 405806A |
| Washer Mfg. Lot Number(s) | 317843 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2-3/4" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | Mech.Zinc Galv. ASTM B695 |
| Diameter/Size | 1/2"x 2-3/4" | Bolt Mfg. Lot Number | 365604A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2020-07-15-3
DIME Test ID: 2020-07-15-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-08-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/18/2020
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1 | 405806A | 23078 | Proff Load | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Proff Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/19/2020 ✔