Summary for Test 2020-05-05-24-5

Test performed: ASTM C185-15a

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/05/2020 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing05/05/2020 Sample typeAnnual Source Testing
A brief description of the sampleType III Cement The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byPlant
Last name of sampler or witnessed byPersonnel Title of sampler
Telephone number of sampler Laboratory sample identificationCM205024
Linked DIME Sample ID The fabricator/manufacturer/facility nameLaFarge Holcim
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandLaFarge Holcim
MillDevils Slide Type of Cementitious MaterialType III Cement

Test Details

DIME Sample ID: 2020-05-05-24
DIME Test ID: 2020-05-05-24-5
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Test Release Date: 2020-09-03

Test Results


Input Type: Measured
Tester's full name: Anthony Valdez Jr
Date of test: 08/13/2020
Specific gravity: 3.15
Water Content: 248
The amount of flow (In percent): 86 %
Gross Weight of Sample: 1568.1 grams
Tare Weight of Sample: 725.3 grams
The amount of water used (In percent): 70.86 %
Net Weight of Sample: 842.8 grams
Theoretical Mass per Unit Volume: 2.25
Actual Mass per Unit Volume: 2.11
Air Content: 6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/3/2020 ✔