Summary for Test 2014-12-31-2-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date12/31/2014 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/06/2015
Sample typeDepartment Acceptance A brief description of the sampleStructure Backfill
The quantity of what the sample constitutes1 Bag From where was the sample collectedOther
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byChoi
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification5000B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJobsite Transportation Laboratory (TL) NumberC686458
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SW corner of Burbank Blvd
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedJobsite
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-12-31-2
DIME Test ID: 2014-12-31-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2015-02-23

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 01/08/2015
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 97 %
Cumulative percent passing the 1 1/2 in. sieve: 96 %
Cumulative percent passing the 1 in. sieve: 91 %
Cumulative percent passing the 3/4 in. sieve: 84 %
Cumulative percent passing the 1/2 in. sieve: 71 %
Cumulative percent passing the 3/8 in. sieve: 62 %
Cumulative percent passing the #4 sieve: 46 %
Cumulative percent passing the #8 sieve: 36 %
Cumulative percent passing the #16 sieve: 29 %
Cumulative percent passing the #30 sieve: 22 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 10 %
Cumulative percent passing the #200 sieve: 7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/23/2015