Summary for Test 2020-05-01-18-3
Test performed: ASTM C109-16aProject Information
| Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/01/2020 | Sample Unique Key | 18 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/01/2020 | Sample type | Annual Source Testing |
| A brief description of the sample | natural pozzolan | The quantity of what the sample constitutes | 1 Bucket |
| From where was the sample collected | Source | First name of sampler or witnessed by | Plant |
| Last name of sampler or witnessed by | Personnel | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | CM205001 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | 3M | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | 3M |
|---|---|---|---|
| Mill | NP200C | Type of Cementitious Material | Class F or N Flyash |
Test Details
DIME Sample ID: 2020-05-01-18
DIME Test ID: 2020-05-01-18-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2021-06-24
Test Results
Will control cubes be used per ASTM C311?: yes
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 08/03/2020
Age of specimen: 28 days
The amount of flow : 115 %
The amount of water used : 50.0 %
Compressive strength of 1st specimen : 4195 psi
Compressive strength of 2nd specimen: 4193 psi
Compressive strength of 3rd specimen : 4509 psi
Average Compressive strength (to nearest 10 psi): 4300 psi
Average Compressive strength (to nearest 10 psi) control group: 6060 psi
Strength Activity Index of Portland Cement per ASTM C109: 71 %
General comments (publicly viewable) (Max 1000 characters): 28 day test
Test was verified on 6/24/2021 ✔