Summary for Test 2020-07-09-35-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date07/09/2020 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing07/29/2020 Sample typeQuality Assurance
A brief description of the sampleHRC 500/510 The quantity of what the sample constitutes36
From where was the sample collectedDistributor First name of sampler or witnessed byKen
Last name of sampler or witnessed byVarela Title of samplerASI
Telephone number of sampler(562) 440-7716 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameIntegrity Rebar Placers
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL08-065-20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorIntegrity Rebar Placers
Rebar Size#4 Coupler Model500/510
Coating StandardsUncoated Shape of RebarHoop
Rebar Hoop Diameter Rebar Hoop FabricatorIntegrity Rebar Placers
Coupler Component Heat/Lot Number(s)A190833 / 10079113 Rebar Heat Number(s)6503051602
Rebar Size 2 4 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2020-07-09-35
DIME Test ID: 2020-07-09-35-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-07-29

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/29/2020
UTM: 75kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1114/13mm0.219695.6498478OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 7/29/2020