Summary for Test 2020-07-06-5-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214228
DEA: 120N4904
EFIS: 1214000050
DIST-CO-RTE-PM12-ORA-91-R12.5/R13.9
Award Date11/29/2022
Closeout Date11/07/2023
Work DescriptionVEHICLE ENFORCEMENT FACILITY IMPROVEMENT AT PERALTA WEIGH STATION.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 1.0 MILE EAST OF ROUTE 91/90 SEPARATION TO 0.5 MILE WEST OF WEIR CANYON ROAD UNDERCROSSING
QA Service Level1 (Verified on 08/13/2019)

Sample Information

Sample Taken Date07/06/2020 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing07/10/2020 Sample typeVerification
A brief description of the sampleASTM A325 5/8"-11 x 2" The quantity of what the sample constitutes38
From where was the sample collectedDistributor First name of sampler or witnessed byKenneth
Last name of sampler or witnessed byVarela Title of samplerAssociate Steel Inspector
Telephone number of sampler5624407716 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBristol Machine
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL08-063-20
Structure unique identifier Structure namePERALTA WEIGH STATION
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Fontana Gruppo Nut Mfg. Lot Number(s)31980-215104804
Washer Mfg. Lot Number(s)143434 Bolt SpecificationASTM A325
Bolt Length(s)2" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishBlack
Diameter/Size5/8" - 11 Bolt Mfg. Lot NumberL073L1
Rocap Test Requirement(s)unknown Lubricant Requirements(s)None
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2020-07-06-5
DIME Test ID: 2020-07-06-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-07-22

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/21/2020
UTM: 400kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1131980-21510480439620Nut Prooffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 7/22/2020 ✔