Summary for Test 2018-11-01-3-6

Test performed: ASTM C109-16a

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/01/2018 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing11/01/2018 Sample typeAnnual Source Testing
A brief description of the sampleClass F Flyash The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationCM185842
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCharah
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeCementitious BrandCharah
MillDynegy Miami Fort 7 Type of Cementitious MaterialClass F or N Flyash

Test Details

DIME Sample ID: 2018-11-01-3
DIME Test ID: 2018-11-01-3-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2020-07-17

Test Results


Will control cubes be used per ASTM C311?: yes
Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 03/19/2018
Age of specimen: 28 days
The amount of flow : 108 %
The amount of water used : 48.0 %
Compressive strength of 1st specimen : 4224 psi
Compressive strength of 2nd specimen: 3918 psi
Compressive strength of 3rd specimen : 4433 psi
Average Compressive strength (to nearest 10 psi): 4330 psi
Average Compressive strength (to nearest 10 psi) control group: 5030 psi
Strength Activity Index of Portland Cement per ASTM C109: 86 %
General comments (publicly viewable) (Max 1000 characters): Specimen 2 outside allowable limits. Two cube average presented.

Test was verified on 7/17/2020