Summary for Test 2020-07-02-8-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0.0/21.8 |
| Award Date | 12/03/2019 |
| Closeout Date | 09/28/2022 |
| Work Description | San Mateo US 101 Express Lanes North |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 07/02/2020 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/09/2020 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolt Assembly |
| The quantity of what the sample constitutes | 127 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
| Title of sampler | QAI | Telephone number of sampler | 562-480-6984 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-003-20 | Structure unique identifier | |
| Structure name | HOV Rte 101 | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 061020BR |
|---|---|---|---|
| Heat Number(s) | DL17106416 | Nut Mfg. Lot Number(s) | 27724-75070238 |
| Washer Mfg. Lot Number(s) | 5737 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 4.75" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1-1/2"-6 | Bolt Mfg. Lot Number | 215795 |
| Rocap Test Requirement(s) | 240 degrees | Lubricant Requirements(s) | yes on nuts |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2020-07-02-8
DIME Test ID: 2020-07-02-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-07-15
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/14/2020
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 215795 | 1.5000 | 198166 | 881.48 | 6.00 | A325 | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Bluehill Data Point FileTest was verified on 7/15/2020 ✔