Summary for Test 2020-06-25-18-2

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 214314
DEA: 081F6904
EFIS: 0815000016
DIST-CO-RTE-PM08-RIV-79-0.0/15.6
Award Date10/02/2019
Closeout Date03/23/2021
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA-G.
Location DescriptionRIVERSIDE COUNTY NEAR TEMECULA FROM SAN DIEGO COUNTY LINE TO 0.4 MILE EAST OF BUTTERFIELD STAGE ROAD
QA Service Level1 (Verified on 12/12/2019)

Sample Information

Sample Taken Date06/25/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2020
Sample typeDepartment Acceptance A brief description of the sampleAC Drum Aggregate
The quantity of what the sample constitutes1 bag combined aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byQC Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedbelt an chute
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design number106835 Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-25-18
DIME Test ID: 2020-06-25-18-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-07-03

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: I. NAJJAR
Date of test: 07/26/2020
Sand Equivalent (Test 1): 76
Sand Equivalent (Test 2): 80
Sand Equivalent (Test 3): 79
Sand Equivalent: 79
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/3/2020