Summary for Test 2020-05-11-13-7

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date05/11/2020 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing05/14/2020 Sample typeVerification
A brief description of the sample1/2 RHMA-G-SP Aggregate The quantity of what the sample constitutesJMF 6 Bags
From where was the sample collectedManufacturer First name of sampler or witnessed byJay
Last name of sampler or witnessed byOlsen Title of sampler
Telephone number of sampler Laboratory sample identification0214G-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials Sun Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sampleUnknown
The plant number326120 SVA3 VLO A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-11-13
DIME Test ID: 2020-05-11-13-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-06-02

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 05/26/2020
Weighted percentage of particles (by mass) that were flat and elongated: 0 %
Weighted percentage of particles (by mass) that were not flat and elongated: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/2/2020