Summary for Test 2020-04-14-30-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date04/14/2020 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/14/2020
Sample typeDepartment Acceptance A brief description of the sampleWCS Aggregate Acceptance
The quantity of what the sample constitutes1 bag 160 cy From where was the sample collectedManufacturer
First name of sampler or witnessed byMD Last name of sampler or witnessed byShajahan
Title of samplerMREA Telephone number of sampler
Laboratory sample identification9724 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSource Vulcan Sunvalley, Sampled from Security Paving Burbank Transportation Laboratory (TL) Number944446
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)00-00-0000
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedSecurity Paving OnSite
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberG3-16-PCC002 Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-14-30
DIME Test ID: 2020-04-14-30-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-05-11

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 04/22/2020
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.9
Sand reading (test 1): 4.3
Clay reading (test 2): 5
Sand reading (test 2): 4.2
Sand equivalent (test 1): 88
Sand equivalent (test 2): 84
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/11/2020