Summary for Test 2020-04-14-30-2
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 04/14/2020 | Sample Unique Key | 30 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/14/2020 |
Sample type | Department Acceptance | A brief description of the sample | WCS Aggregate Acceptance |
The quantity of what the sample constitutes | 1 bag 160 cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | MD | Last name of sampler or witnessed by | Shajahan |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 9724 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Source Vulcan Sunvalley, Sampled from Security Paving Burbank | Transportation Laboratory (TL) Number | 944446 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00-00-0000 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Security Paving OnSite |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | fine |
The concrete mix design number | G3-16-PCC002 | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-04-14-30
DIME Test ID: 2020-04-14-30-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-05-11
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 04/22/2020
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.9
Sand reading (test 1): 4.3
Clay reading (test 2): 5
Sand reading (test 2): 4.2
Sand equivalent (test 1): 88
Sand equivalent (test 2): 84
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/11/2020 ✔