Summary for Test 2020-04-22-5-5
Test performed: CTM 211-May 2010Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 04/22/2020 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/27/2020 |
Sample type | Verification | A brief description of the sample | 3/4 HMA-A R10 Aggregates and RAP |
The quantity of what the sample constitutes | PSUE 12 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Aaron | Last name of sampler or witnessed by | Maravilla |
Title of sampler | Plant QC | Telephone number of sampler | |
Laboratory sample identification | 0200A-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Sun Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0019, 91-19-0021 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A R10 | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | 220805 SVA VLO | A detailed description of where the material sample was collected | Belt Cut at Vulcan Sun Valley Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-04-22-5
DIME Test ID: 2020-04-22-5-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2020-05-06
Test Results
How many revolutions are required?: Both Tests
Input Type: Calculated
Tester's full name: Husni Ankir
Date of test: 04/30/2020
Grading: B
Percent wear (100 Rev Test): 3 %
Percent wear (500 Rev Test): 36 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/6/2020 ✔