Summary for Test 2020-04-15-1-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 214587 DEA: 101J1604 EFIS: 1018000180 |
|---|---|
| DIST-CO-RTE-PM | 10-STA-132-27.9/41.0 |
| Award Date | 03/02/2020 |
| Closeout Date | 04/26/2021 |
| Work Description | COLD PLANE AC PAVEMENT, RHMA OVERLAY AND SLURRY SEAL. |
| Location Description | STANISLAUS COUNTY IN AND NEAR WATERFORD FROM G STREET TO 1.2 MILES EAST OF RUSHING ROAD |
| QA Service Level | 1 (Verified on 01/24/2020) |
Sample Information
| Sample Taken Date | 04/15/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/15/2020 |
| Sample type | Verification | A brief description of the sample | Type A HMA with RAP |
| The quantity of what the sample constitutes | 16 boxes of 1/2" Type A HMA with RAP | From where was the sample collected | Source |
| First name of sampler or witnessed by | J | Last name of sampler or witnessed by | Kort |
| Title of sampler | Technician | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | George Reed Inc | Transportation Laboratory (TL) Number | C033878 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | Unknown |
| Sublot number | Unknown | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2020-04-15-1
DIME Test ID: 2020-04-15-1-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-04-22
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Frank Chavez Jr
Date of test: 04/17/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1526.7 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.58 %
Moisture Content: 0.23 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.23 %
General comments (publicly viewable) (Max 1000 characters):