Summary for Test 2020-04-08-1-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/08/2020 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/14/2020 |
| Sample type | Stock | A brief description of the sample | 3/4" x 5 1/2" F3125 / A153 / F2329 Hex Bolts HDG |
| The quantity of what the sample constitutes | 403 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
| Title of sampler | QA | Telephone number of sampler | 213 435 4055 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-088-20 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 100894992 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | F3125 / A153 / F2329 | |
| Bolt Length(s) | 5 1/2" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | Hot Dipped Galvanized |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | G9864 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2020-04-08-1
DIME Test ID: 2020-04-08-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-04-16
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/15/2020
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2 | G9864 | 0.7500 | 48504 | 215.76 | 10.00 | A325 Bolt | bewing |
General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point FileTest was verified on 4/16/2020 ✔