Summary for Test 2019-12-30-16-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date12/30/2019 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/31/2019
Sample typeDepartment Acceptance A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes1 BUCKET From where was the sample collectedDistributor
First name of sampler or witnessed byMD Last name of sampler or witnessed byShahjahan
Title of samplerMREA Telephone number of sampler
Laboratory sample identification9077 Linked DIME Sample ID2019-12-30-16
The fabricator/manufacturer/facility nameVULCAN SUN VALLEY Transportation Laboratory (TL) NumberC91437
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedunknown
Where the material sample would have been placed if not sampledRTE 5 SBB EMPIRE PHASE 4 Primary Aggregate Nominal Sizefine
The concrete mix design numberS72017 Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-12-30-16
DIME Test ID: 2019-12-30-16-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-03-20

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: DANILLO FERRER
Date of test: 01/07/2020
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.6
Sand reading (test 1): 4.4
Clay reading (test 2): 5.4
Sand reading (test 2): 4.2
Sand equivalent (test 1): 79
Sand equivalent (test 2): 78
Sand equivalent before temperature correction: 79
Sand equivalent after temperature correction: 79
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/20/2020