Summary for Test 2020-02-13-13-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 213763
DEA: 060Q19A4
EFIS: 0613000152
DIST-CO-RTE-PM06-KER-58-R99.0/R100.3
Award Date02/04/2019
Closeout Date10/22/2021
Work DescriptionWIDEN SHOULDERS AND REPLACE BRIDGES
Location DescriptionKERN COUNTY NEAR TEHACHAPI FROM 0.5 MILE WEST TO 0.8 MILE EAST OF SAND CANYON UNDERCROSSING
QA Service Level1 (Verified on 01/09/2019)

Sample Information

Sample Taken Date02/13/2020 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing02/14/2020 Sample typeDepartment Acceptance
A brief description of the sample3/4 HMA-A-SP R15 The quantity of what the sample constitutes3 boxes
From where was the sample collectedManufacturer First name of sampler or witnessed byQC
Last name of sampler or witnessed byqc Title of sampler
Telephone number of sampler Laboratory sample identification0137A-20
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Construction Arvin Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2020-02-13-13
DIME Test ID: 2020-02-13-13-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-02-19

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 02/19/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 4.71 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/19/2020 ✔