Summary for Test 2019-12-26-3-2
Test performed: ASTM D412-06a-re13Project Information
| Project Identifiers | Project ID: 213749 DEA: 120C1104 EFIS: 1200000633 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-20.3/21.6 |
| Award Date | 04/19/2019 |
| Closeout Date | 05/28/2024 |
| Work Description | SR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
| Sample Taken Date | 12/26/2019 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/06/2020 | Sample type | Quality Assurance |
| A brief description of the sample | elastomeric bearing pad | The quantity of what the sample constitutes | 11 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Howard |
| Last name of sampler or witnessed by | Sternberg | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Scougal Rubber | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | 18009-2 |
|---|---|---|---|
| Material/Compound/Elastomer ID | na | Samples Representing | 11 |
| Description (size) | 3x20x20 | Comments | Unknown |
| Description (Number of Shims) | 6 | Type of Bearing Pad | Steel |
| Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Scougal Rubber |
| Batch Number | na |
Test Details
DIME Sample ID: 2019-12-26-3
DIME Test ID: 2019-12-26-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2020-01-14
Test Results
Number of specimens tested: 3
Unit of the Ultimate Tensile Values: lbf per sqr in
Input Type: Calculated
Tester's full name: randelin
Date of test: 01/08/2020
UTM: 2kip
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.081
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2626.65 lbf/in^2
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.079
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2631.68 lbf/in^2
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.082
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2523.86 lbf/in^2
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2626.7 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Sample 3
Source: Bluehill Data Point File
Test graph for Sample 2
Source: Bluehill Data Point File
Test graph for Sample 1
Test was verified on 1/14/2020 ✔