Summary for Test 2019-02-22-16-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date02/22/2019 Sample Unique Key16
Date that the sample was received by the laboratory/organization performing the testing02/22/2019 Sample typeVerification
A brief description of the sample1/2" RHMA-O The quantity of what the sample constitutesJMF Verification
From where was the sample collectedSource First name of sampler or witnessed byDan
Last name of sampler or witnessed byWeaver Title of sampler
Telephone number of sampler Laboratory sample identification19-J-002
Linked DIME Sample ID The fabricator/manufacturer/facility nameSierra Pacific - Avenal
Transportation Laboratory (TL) NumberC955245 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2019-02-22-16
DIME Test ID: 2019-02-22-16-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-12-31

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 02/22/2019
Test procedure used?: Method B
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1000.0 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 914.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.91 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 7.67 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/31/2019 ✔