Summary for Test 2019-12-04-4-2
Test performed: ASTM F606-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 12/04/2019 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/09/2019 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4"x9" A449 Threaded Rod | The quantity of what the sample constitutes | 570 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Muser | Title of sampler | QA |
| Telephone number of sampler | 9165170532 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | UIS | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-411-19 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 10592570 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | A449 |
| Bolt Length(s) | 9" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | HDG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 32543 |
| Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-12-04-4
DIME Test ID: 2019-12-04-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-12-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/10/2019
UTM: 400kip
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1B | UNC 3/4 | 0.334 | 44253 | 196 | 132495 | 119967 | 40069 | A449 Tensile |
General comments (publicly viewable) (Max 1000 characters): A449 Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 12/11/2019 ✔