Summary for Test 2019-12-04-3-2
Test performed: ASTM F606-14Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/04/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/09/2019 |
Sample type | Quality Assurance | A brief description of the sample | 5/8"x12" A449 Threaded Rod |
The quantity of what the sample constitutes | 504 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-411-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 10539450 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | A449 |
Bolt Length(s) | 12" | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 5/8" | Bolt Mfg. Lot Number | 32498 |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
Test Details
DIME Sample ID: 2019-12-04-3
DIME Test ID: 2019-12-04-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-12-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/10/2019
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1B | UNC 5/8 | 0.226 | 31059 | 138 | 137430 | 123391 | 27886 | A449 Tensile |
General comments (publicly viewable) (Max 1000 characters): A449 Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 12/11/2019 ✔