Summary for Test 2019-11-20-4-8
Test performed: ASTM B499-14Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/20/2019 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/27/2019 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts | The quantity of what the sample constitutes | 48 Bolts |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Weeks | Title of sampler | ASI |
| Telephone number of sampler | 310-883-8369 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | A and M Nut and Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-192-19 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA |
|---|---|---|---|
| Heat Number(s) | 3083252 | Nut Mfg. Lot Number(s) | 31071-71079609 |
| Washer Mfg. Lot Number(s) | 313289 | Bolt Specification | F1554 Gr. 55 |
| Bolt Length(s) | 42" | Nut Specification | A563 Gr. DH |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1 1/4" -7 | Bolt Mfg. Lot Number | NA |
| Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-11-20-4
DIME Test ID: 2019-11-20-4-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-12-05
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 12/03/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 3083252
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW
Size: 1.25 in
Bolt Length: 42 in
Measurement Average: 6.36 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/5/2019 ✔