Summary for Test 2019-10-31-14-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 214141 DEA: 081J1204 EFIS: 0817000208 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15,91,215-Var |
| Award Date | 06/13/2019 |
| Closeout Date | 02/07/2020 |
| Work Description | REMOVE, PREPARE AND FURNISH POLYESTER CONCRETE OVERLAY. |
| Location Description | RIVERSIDE COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 08/23/2019) |
Sample Information
| Sample Taken Date | 10/31/2019 | Sample Unique Key | 14 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/14/2019 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolt |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Mahlon | Last name of sampler or witnessed by | Lindenmuth |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Midwest Structural Products | Transportation Laboratory (TL) Number | C719377 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S46-922-19 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 100896901 DL18101165 211887 | Nut Mfg. Lot Number(s) | 406871A |
| Washer Mfg. Lot Number(s) | C6542D | Bolt Specification | A325 |
| Bolt Length(s) | 2.25" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | .75" | Bolt Mfg. Lot Number | 424370B |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2019-10-31-14
DIME Test ID: 2019-10-31-14-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-11-15
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 11/14/2019
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1 | 406871A | 51042 | A563 DH Nut | fsaylor |
General comments (publicly viewable) (Max 1000 characters): A563 DH Nut
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 11/15/2019 ✔