Summary for Test 2019-10-29-32-1

Test performed: ASTM F606-14a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/29/2019 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing11/06/2019
Sample typeStock A brief description of the sample1-1/4" x 13" All Thread Stud
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed byRommoney Last name of sampler or witnessed byWu
Title of samplerAMR Telephone number of sampler9164257894
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAM Nut and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)1201010573 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationASTM
Bolt Length(s)13" Nut SpecificationASTM
Washer SpecificationASTM Finish
Diameter/Size1-1/4"x13" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-10-29-32
DIME Test ID: 2019-10-29-32-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-11-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: randelin
Date of test: 11/07/2019
UTM: 400kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A30569-75072703170655nut proof loadrandelin

General comments (publicly viewable) (Max 1000 characters): nut proof load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 11/12/2019