Summary for Test 2019-10-29-30-5
Test performed: ASTM D4791-10Project Information
| Project Identifiers | Project ID: 214136 DEA: 010F3604 EFIS: 0115000115 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-101-R39.2/R48.3 |
| Award Date | 07/31/2019 |
| Closeout Date | 01/04/2021 |
| Work Description | COLD PLANE AC PAVEMENT, RHMA OVERLAY, AND GUARDRAIL INSTALLATION. |
| Location Description | HUMBOLDT COUNTY NEAR REDCREST, PEPPERWOOD, AND STAFFORD FROM ENGLWOOD PARK UNDERCROSSING TO EEL RIVER BRIDGE AND OVERHEAD |
| QA Service Level | 1 (Verified on 06/24/2019) |
Sample Information
| Sample Taken Date | 10/29/2019 | Sample Unique Key | 30 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/29/2019 |
| Sample type | Quality Control | A brief description of the sample | Coldfeed |
| The quantity of what the sample constitutes | JMF | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Matt | Last name of sampler or witnessed by | Horn |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Mercer Fraser B | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-12-0002::SANDY PRAIRIE |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Cold Feed |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-10-29-30
DIME Test ID: 2019-10-29-30-5
Testing Lab: Trinity Engineering Laboratories, Incorporated - Fresno
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-10-29
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Matthew Horn
Date of test: 10/29/2019
Weighted percentage of particles (by mass) that were flat and elongated: 1.6 %
Weighted percentage of particles (by mass) that were not flat and elongated: 98.4 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/29/2019 ✔