Summary for Test 2019-10-16-6-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 10/16/2019 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2019 |
Sample type | Department Acceptance | A brief description of the sample | A490 Bolts |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Emami |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | LeJeune | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 75073905 6214661005 140647 75067668 10508080 6214506106 262342 75070176 6214552009 277861 | Nut Mfg. Lot Number(s) | 30581-6214661005 28846-6214661005 27185-6214506106 27807-6214552009 |
Washer Mfg. Lot Number(s) | 0115-716 D3644 114 D4851 | Bolt Specification | A490 |
Bolt Length(s) | 6" 7" 10" | Nut Specification | A563 DH |
Washer Specification | F436 | Finish | Geomet |
Diameter/Size | 1.25" | Bolt Mfg. Lot Number | 050919-4FM 041719-1CM 051519-7EM 27128-105 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-10-16-6
DIME Test ID: 2019-10-16-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-10-29
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/23/2019
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2A | 041719-1CM | 1.2500 | 150386 | 668.95 | 6.00 | A490 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A490 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 10/29/2019 ✔